Proline T-Mass F 300 Thermal Mass Flow Meter

Features

  • DN 15 to 100 (1/2 to 4in) nominal diameter range
  • 1.1 to 8250 lb/h (0.5 to 3750 kg/h) measuring range
  • Maximum measured error for gas:
    10 to 100% full scale flow: ±1.0% of reading
    1 to 10% full scale flow: ±0.1% of full scale
  • PN 40, Cl. 300, 20K maximum process pressure
  • -40 to 356°F (-40 to 180°C) medium temperature range
  • ±0.25% of reading for velocities above 3.3 ft/s repeatability
  • HART or Modbus RS485 digital communication
  • IP66/67, type 4X enclosure protection
  • ATEX, cCSAus, IECEx, NEPSI, JPN
  • Backlit display with touch control and WLAN access